{"title":"Centrifuges","description":"\u003ch2\u003eCentrifuges for Sale - New and Refurbished | mLab Supply\u003c\/h2\u003e\u003cp\u003eCentrifuges are essential separation instruments used across research, clinical, biotech, and pharmaceutical laboratories. mLab Supply sources new, refurbished, and surplus centrifuges across all major categories - from high-throughput benchtop units to refrigerated and ultracentrifuge configurations - for labs of all sizes and throughput requirements.\u003c\/p\u003e\u003ch3\u003eCommon Use Cases\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCell pellet collection and cell washing workflows\u003c\/li\u003e\n\u003cli\u003ePlasma and serum separation from whole blood\u003c\/li\u003e\n\u003cli\u003eProtein precipitation and clarification\u003c\/li\u003e\n\u003cli\u003eDNA, RNA, and nucleic acid isolation protocols\u003c\/li\u003e\n\u003cli\u003eDensity gradient separations and subcellular fractionation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCentrifuge Categories We Source\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenchtop Centrifuges:\u003c\/strong\u003e General-purpose units for tubes from 1.5 mL to 50 mL; speeds typically up to 6,000 x g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrocentrifuges:\u003c\/strong\u003e Compact units for 0.5-2.0 mL microtubes; speeds up to 21,000 x g for high-speed pelleting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerated Centrifuges:\u003c\/strong\u003e Temperature-controlled units for temperature-sensitive samples; available in benchtop and floor-standing configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed and Ultracentrifuges:\u003c\/strong\u003e Available to source for specialized applications - contact us for availability\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBrands We Source\u003c\/h3\u003e\u003cp\u003eThermo Fisher (Sorvall, Heraeus, Megafuge) | Eppendorf (5810R, 5424R, 5810) | Beckman Coulter (Allegra, Avanti) | Hettich | Andreas Hettich\u003c\/p\u003e\u003ch3\u003eCondition Options\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNew (select models available to source)\u003c\/li\u003e\n\u003cli\u003eRefurbished \/ Pre-Owned - rotor inspected, speed-verified, and tested\u003c\/li\u003e\n\u003cli\u003eSurplus \/ As-Is - priced accordingly\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAvailability and pricing are subject to change. Submit a quote request and we will confirm current stock, lead time, and rotor compatibility within 1-2 business days.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/fr\/pages\/request-a-quote\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"thermo-scientific-sorvall-legend-rt-refrigerated-centrifuge","title":"Thermo Scientific Sorvall Legend RT Refrigerated Centrifuge","description":"\u003cp data-start=\"329\" data-end=\"664\"\u003eThe \u003cstrong data-start=\"333\" data-end=\"396\"\u003eThermo Scientific Sorvall Legend RT Refrigerated Centrifuge\u003c\/strong\u003e is a high-performance, benchtop centrifuge designed for reliable separation of biological samples in a wide range of laboratory environments. Known for its durability and consistent performance, the Legend RT is widely used in clinical, research, and industrial labs.\u003c\/p\u003e\n\u003cp data-start=\"666\" data-end=\"1069\"\u003eThis unit is configured with a \u003cstrong data-start=\"697\" data-end=\"719\"\u003eswing-bucket rotor\u003c\/strong\u003e and includes \u003cstrong data-start=\"733\" data-end=\"744\"\u003ebuckets\u003c\/strong\u003e, making it suitable for routine sample processing such as blood, plasma, and other biological materials. The centrifuge features a \u003cstrong data-start=\"876\" data-end=\"905\"\u003edigital control interface\u003c\/strong\u003e for precise speed and time settings, and its \u003cstrong data-start=\"951\" data-end=\"975\"\u003erefrigerated chamber\u003c\/strong\u003e supports temperature-sensitive samples requiring controlled conditions during centrifugation.\u003c\/p\u003e\n\u003cp data-start=\"1071\" data-end=\"1105\"\u003eThe Legend RT is commonly used in:\u003c\/p\u003e\n\u003cul data-start=\"1106\" data-end=\"1266\"\u003e\n\u003cli data-start=\"1106\" data-end=\"1143\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1143\"\u003eMedical and clinical laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1144\" data-end=\"1179\"\u003e\n\u003cp data-start=\"1146\" data-end=\"1179\"\u003ePathology and microbiology labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1180\" data-end=\"1219\"\u003e\n\u003cp data-start=\"1182\" data-end=\"1219\"\u003eBiological and biochemical research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1220\" data-end=\"1266\"\u003e\n\u003cp data-start=\"1222\" data-end=\"1266\"\u003eNeurological and life science applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1268\" data-end=\"1491\"\u003eThermo Scientific instruments are recognized globally for their engineering quality and long service life, making this centrifuge a dependable addition for laboratories seeking a cost-effective, professional-grade solution.\u003c\/p\u003e\n\u003ch3 data-start=\"1493\" data-end=\"1526\"\u003eCondition \u0026amp; Operational Notes\u003c\/h3\u003e\n\u003cul data-start=\"1527\" data-end=\"1945\"\u003e\n\u003cli data-start=\"1527\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1529\" data-end=\"1563\"\u003eUnit powers on and \u003cstrong data-start=\"1548\" data-end=\"1563\"\u003eruns strong\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1586\"\u003e\n\u003cp data-start=\"1566\" data-end=\"1586\"\u003e\u003cstrong data-start=\"1566\" data-end=\"1586\"\u003eBuckets included\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1589\" data-end=\"1644\"\u003eLid hydraulic mechanism \u003cstrong data-start=\"1613\" data-end=\"1644\"\u003erequires service or rebuild\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1709\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1709\"\u003eHydraulic issue \u003cstrong data-start=\"1663\" data-end=\"1709\"\u003edoes not affect centrifugation performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1882\"\u003e\n\u003cp data-start=\"1712\" data-end=\"1882\"\u003eIf the lid does not close neatly, the unit may not recognize the lid as fully closed; this is typically resolved by a simple \u003cstrong data-start=\"1837\" data-end=\"1882\"\u003epower cycle and reopening\/closing the lid\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1883\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1885\" data-end=\"1945\"\u003eIssue is considered a \u003cstrong data-start=\"1907\" data-end=\"1945\"\u003eminor, serviceable mechanical item\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1947\" data-end=\"1984\"\u003eImportant Sale Terms \u0026amp; Disclaimer\u003c\/h3\u003e\n\u003cp data-start=\"1985\" data-end=\"2234\"\u003eThis item is sold \u003cstrong data-start=\"2003\" data-end=\"2041\"\u003eAS IS \/ WHERE IS \/ WITH ALL FAULTS\u003c\/strong\u003e, with \u003cstrong data-start=\"2048\" data-end=\"2084\"\u003eno warranties or representations\u003c\/strong\u003e, express or implied. No warranty is made regarding fitness for a particular purpose, merchantability, non-infringement, or operational suitability.\u003c\/p\u003e\n\u003cp data-start=\"2236\" data-end=\"2502\"\u003eAll descriptions are provided for informational purposes only. The buyer is solely responsible for conducting their own inspection, testing, and due diligence prior to purchase. No oral or written statement shall be deemed a warranty or representation of any kind.\u003c\/p\u003e\n\u003cp data-start=\"2504\" data-end=\"2660\"\u003eProspective buyers are encouraged to contact \u003cstrong data-start=\"2549\" data-end=\"2564\"\u003emLab Supply\u003c\/strong\u003e directly with any questions regarding configuration, condition, or logistics prior to purchase.\u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"Default Title","offer_id":47308521078958,"sku":null,"price":565.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1012\/4206\/files\/centrifuge.jpg?v=1767163045"},{"product_id":"beckman-coulter-type-50-2-ti-fixed-angle-centrifuge-rotor","title":"Beckman Coulter Type 50.2 Ti Fixed-Angle Centrifuge Rotor","description":"\u003ch3 data-start=\"186\" data-end=\"200\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"201\" data-end=\"485\"\u003eThe \u003cstrong data-start=\"205\" data-end=\"237\"\u003eBeckman Coulter Type 50.2 Ti\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"260\" data-end=\"290\"\u003etitanium fixed-angle rotor\u003c\/strong\u003e designed for ultra-high-speed centrifugation. It’s widely used in molecular biology, biochemistry, and virology labs for applications requiring extreme centrifugal force and chemical resistance.\u003c\/p\u003e\n\u003cp data-start=\"487\" data-end=\"652\"\u003eManufactured from \u003cstrong data-start=\"505\" data-end=\"523\"\u003esolid titanium\u003c\/strong\u003e, this rotor offers excellent durability, corrosion resistance, and long service life under demanding ultracentrifuge conditions.\u003c\/p\u003e\n\u003chr data-start=\"654\" data-end=\"657\"\u003e\n\u003ch3 data-start=\"659\" data-end=\"683\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"684\" data-end=\"1074\"\u003e\n\u003cli data-start=\"684\" data-end=\"715\"\u003e\n\u003cp data-start=\"686\" data-end=\"715\"\u003e\u003cstrong data-start=\"686\" data-end=\"701\"\u003eRotor Type:\u003c\/strong\u003e Fixed-Angle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"716\" data-end=\"747\"\u003e\n\u003cp data-start=\"718\" data-end=\"747\"\u003e\u003cstrong data-start=\"718\" data-end=\"731\"\u003eMaterial:\u003c\/strong\u003e Titanium (Ti)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"748\" data-end=\"791\"\u003e\n\u003cp data-start=\"750\" data-end=\"791\"\u003e\u003cstrong data-start=\"750\" data-end=\"768\"\u003eMaximum Speed:\u003c\/strong\u003e Up to \u003cstrong data-start=\"775\" data-end=\"789\"\u003e50,000 RPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"792\" data-end=\"853\"\u003e\n\u003cp data-start=\"794\" data-end=\"853\"\u003e\u003cstrong data-start=\"794\" data-end=\"810\"\u003eMaximum RCF:\u003c\/strong\u003e ~\u003cstrong data-start=\"812\" data-end=\"827\"\u003e200,000 x g\u003c\/strong\u003e (application-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"854\" data-end=\"913\"\u003e\n\u003cp data-start=\"856\" data-end=\"913\"\u003e\u003cstrong data-start=\"856\" data-end=\"874\"\u003eTube Capacity:\u003c\/strong\u003e \u003cstrong data-start=\"875\" data-end=\"889\"\u003e8 × ~39 mL\u003c\/strong\u003e (tube type dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"914\" data-end=\"937\"\u003e\n\u003cp data-start=\"916\" data-end=\"937\"\u003e\u003cstrong data-start=\"916\" data-end=\"926\"\u003eAngle:\u003c\/strong\u003e ~\u003cstrong data-start=\"928\" data-end=\"935\"\u003e23°\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"938\" data-end=\"993\"\u003e\n\u003cp data-start=\"940\" data-end=\"993\"\u003e\u003cstrong data-start=\"940\" data-end=\"962\"\u003eTemperature Range:\u003c\/strong\u003e Typically \u003cstrong data-start=\"973\" data-end=\"991\"\u003e–20°C to +40°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"994\" data-end=\"1019\"\u003e\n\u003cp data-start=\"996\" data-end=\"1019\"\u003e\u003cstrong data-start=\"996\" data-end=\"1013\"\u003eVacuum Rated:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1020\" data-end=\"1074\"\u003e\n\u003cp data-start=\"1022\" data-end=\"1074\"\u003e\u003cstrong data-start=\"1022\" data-end=\"1039\"\u003eAutoclavable:\u003c\/strong\u003e No (chemical cleaning recommended)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1076\" data-end=\"1079\"\u003e\n\u003ch3 data-start=\"1081\" data-end=\"1130\"\u003eCompatible Beckman Coulter Ultracentrifuges\u003c\/h3\u003e\n\u003cp data-start=\"1131\" data-end=\"1212\"\u003eCommonly used with Beckman Coulter \u003cstrong data-start=\"1166\" data-end=\"1200\"\u003eOptima series ultracentrifuges\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"1213\" data-end=\"1285\"\u003e\n\u003cli data-start=\"1213\" data-end=\"1232\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1232\"\u003eOptima L-series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1233\" data-end=\"1285\"\u003e\n\u003cp data-start=\"1235\" data-end=\"1285\"\u003eOptima LE-80K \/ XE \/ MAX-XP (verify configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1287\" data-end=\"1375\"\u003e(Compatibility may vary by instrument and drive hub—always confirm before installation.)\u003c\/p\u003e\n\u003chr data-start=\"1377\" data-end=\"1380\"\u003e\n\u003ch3 data-start=\"1382\" data-end=\"1408\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"1409\" data-end=\"1594\"\u003e\n\u003cli data-start=\"1409\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1411\" data-end=\"1441\"\u003eViral particle concentration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1471\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1471\"\u003eSubcellular fractionation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1472\" data-end=\"1510\"\u003e\n\u003cp data-start=\"1474\" data-end=\"1510\"\u003eProtein and nucleic acid pelleting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1513\" data-end=\"1543\"\u003eDensity gradient separations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1544\" data-end=\"1594\"\u003e\n\u003cp data-start=\"1546\" data-end=\"1594\"\u003eHigh-speed clarification of biological samples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1596\" data-end=\"1599\"\u003e\n\u003ch3 data-start=\"1601\" data-end=\"1619\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1620\" data-end=\"1874\"\u003e\n\u003cli data-start=\"1620\" data-end=\"1678\"\u003e\n\u003cp data-start=\"1622\" data-end=\"1678\"\u003e\u003cstrong data-start=\"1622\" data-end=\"1652\"\u003eUltra-high RCF performance\u003c\/strong\u003e for demanding protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1738\"\u003e\n\u003cp data-start=\"1681\" data-end=\"1738\"\u003e\u003cstrong data-start=\"1681\" data-end=\"1706\"\u003eTitanium construction\u003c\/strong\u003e resists corrosion and fatigue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1739\" data-end=\"1818\"\u003e\n\u003cp data-start=\"1741\" data-end=\"1818\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1763\"\u003eFixed-angle design\u003c\/strong\u003e enables faster pelleting than swinging-bucket rotors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1819\" data-end=\"1874\"\u003e\n\u003cp data-start=\"1821\" data-end=\"1874\"\u003eTrusted, widely adopted Beckman Coulter rotor model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1876\" data-end=\"1879\"\u003e\n\u003ch3 data-start=\"1881\" data-end=\"1896\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul data-start=\"1897\" data-end=\"2081\"\u003e\n\u003cli data-start=\"1897\" data-end=\"1922\"\u003e\n\u003cp data-start=\"1899\" data-end=\"1922\"\u003eResearch laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1923\" data-end=\"1962\"\u003e\n\u003cp data-start=\"1925\" data-end=\"1962\"\u003eBiotech \u0026amp; pharmaceutical facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1963\" data-end=\"2008\"\u003e\n\u003cp data-start=\"1965\" data-end=\"2008\"\u003eCore labs and university research centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2009\" data-end=\"2081\"\u003e\n\u003cp data-start=\"2011\" data-end=\"2081\"\u003eReplacement or expansion of existing ultracentrifuge rotor inventory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Beckman Coulter","offers":[{"title":"Default Title","offer_id":47366609797294,"sku":null,"price":389.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1012\/4206\/files\/BeckmanCoulter.jpg?v=1768438779"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1012\/4206\/collections\/centrifuges.png?v=1778272608","url":"https:\/\/mlabsupply.com\/fr\/collections\/centrifuges.oembed","provider":"mLab Supply","version":"1.0","type":"link"}